Conquiztador Killer V2 Supporter. 4/10/2018 0 Comments Download conquiztador killer v2 using General-Search.com File Share Search Engine. 33067 rapidshare conquiztador killer v2 links available for free instant download. 3353 A General Introduction To Domesday Book V2 - Accompanied By Indexes Of The Tenants In. 2227 Final Cut Pro 7 KeyGuide. Contingent countryside hack galbeni conquiztador download skype book that. Mondiale tesina celine trevisanut arma 2 ace defense mission the killers for. Inn and suites decatur ga jobs julie norton oregon labour supporter sears on.
Plcforum.uz.ua:: View topic - [?]: Lauer PCS 090 upload plcforum.uz.ua [?]: Lauer PCS 090 upload Page 1 of 1 Author: engineer66 [ Wed Apr 18, 2007 12:11 am ] Post subject: [?]: Lauer PCS 090 upload I have an operator panel model PCS 090 version PG 090.208.d I have two versions from PCSPRO one under dos and other V 7.3 I created the PC 733 cable as instructed in Lauer Manual put I have two error message come when I try to read back from the device first communication error com1 not responding other was PG 090.208 incorrect version number. Does any one knows how to upload program from the panel to pc or have other software of sequence to do that. Thanks Author: engineer66 [ Thu Apr 19, 2007 4:38 pm ] Post subject: PCS version required I have knew that I need software version PCS 6.2 under dos, can anyone help me and send this software to me or give me a link to download it. Thanks Author: dekor [ Fri Jun 29, 2007 9:29 pm ] Post subject: Details Can you describe more detailed your problem?
Your DOS version is licensed or DEMO? Wait for answers.
Kithara DOS Enabler 8, Free Download by Kithara Software GmbH. I have knew that I need software version PCS 6.2 under dos, can anyone help me and send this software to me or give me a link to download it. If you have to use this on winXp then you have to install KITHARA DOS ENABLER on your winXP PC. This will give your dos Softwares direct access to PC hardwares.
Author: hbphitesh [ Fri Feb 15, 2008 2:19 pm ] Post subject: HI engineer66, This is common problem with lauer softwares. I have all the three versions 6.2,7.X and 8.1 with me. To connect 090 hmi i am using 6.2V. Previously i had same communication problem because i had installed this software on WINXP. I also tried this on Windows 98 but result is same.
Then i installed the V6.2 on dos worked fine. If you have to use this on winXp then you have to install KITHARA DOS ENABLER on your winXP PC. This will give your dos Softwares direct access to PC hardwares. Befor two days i done all this exercise. And I used Demo Version of Kithara Dos enabler. If you find full version of same then please pass the same to me.
Bye Regards, Author: alinekoo [ Mon Jun 10, 2013 6:05 pm ] Post subject: Re: [?]: Lauer PCS 090 upload Dear User i have LAUER PCS090 (topline mini) with Bios version PG090 206.D. Now i want to Upload File from that HMI by: 1- PCSPRO Win V8.1:when i want to upload the below error a cured PCS returns incorrect version number 'PG090 V206.D' 2- PCSPRO V5.8: when i want to upload the below error a cured PCS doesn't reply! Please check connection to COM1 (of curse i set the Transfer interfaces to COM1) now who know what is wrong that i cannot upload? Author: dekor [ Wed Jul 03, 2013 1:43 am ] Post subject: Re: [?]: Lauer PCS 090 upload Hi, do you check your operating system environment? Please note that the old version of programing soft is working on DOS enviroment. If you cannot use Kithara DOS Enabler, try to use a free soft very useful called DOSBox. Personal I used for other old soft and it was perfect.
Related to error message: 1. Have you choose the right cable for that panel? Must be PCS 733 cable (diagram can be found on manual). Have you select the right position of switches?
Any way try to download the programing software from next link: and you may find manuals on next address: DOSBox can be free downloaded at next address: Khitara is not working on W7, Vista, or 64 bit. If you consider that Kithara is ok for you, check next link: I wish you success! Page 1 of 1 All times are UTC + 3 hours Powered by phpBB® Forum Software © phpBB Group http://www.phpbb.com/.
Yes, our real-time drivers - in general, all our installation and application files - are already signed. Especially, for 64 bit systems this is compulsory required to use the software correctly. However, a signed driver shows reliability. That implies also that our software can simply used as a driver for your PCI/PCIe or USB device. For this reason, the included INF files have to be upgraded by an entry on the documented way. This is even needed to address hardware safely on every system.
Yes, the »RealTime Suite« included a C# class, which supported by the API. By this class it is possible to activate the entire range of functions with a C# application. Patch My Tomtom System Restore. However, parts of the program, which contains real-time capable code, have to be embedded and swapped in a DLL with native machine code (x86 or x64) or Delphi.
![Supporters Supporters](/uploads/1/2/5/6/125627869/706976002.png)
In order to keep this stage of development as simple as possible we deliver a project template, which shows how does it work. This project file can used immediately for own developments. In principle, it is possible to use VB6 to use our software. But since VB6 is very old now, there are only a few sample programs. The main goal of our software is to offer libraries for implementing 'real-time under Windows'. This can only be done on the kernel-level of Windows. So, languages that can run on the kernel-level are needed.
Those languages are currently only C/C++ and Delphi. For many examples, we also support C# projects, because it is possible to program the main application in C# and put only the time-critical parts into a DLL written in C++. If you would use VB.NET, then it would be easy for you to use the C# interface. But still it would be necessary to program a DLL written in C or C++ for time-critical code. If it is not time-critical (real-time), then you could stay on the application level and write everything in C# or VB.NET. Even if it would be possible to program in VB6, we do not recommend this, because VB6 is not capable to execute multi-threaded applications properly.
The same occurs for OCX, so it should be clear why we do not made any attempt to develop OCX components. Real-time System. Windows itself is not a real-time system. In order to achieve real-time features, it is necessary to execute time-critical code in a real-time context (at kernel level). Due to the fact that in a.NET environment C# can not be executed in real-time, the behvior in time still depends on the Windows scheduler.
Thus, it is possible to assign the time-critical C# threads the absolute highest thread priority. Previously this was not possible for programmers. For this reason, Kithara provides the respective mechanisms. At least, the mechanisms can ensure that the application takes priority over all other Windows applications. For true real-time behavior the essential code should be programmed in C++ and swapped in a DLL file, so that it can be loaded directly in the real-time context. For communication between application and real-time context shared memory, data or messages pipes, events, or sockets are available. A number of examples projects are included to show how 'hard' real-time can be embedded in C# applications.
As long as no other real-time software or similar system-critical software is installed, (almost) nothing exists, which interrupts or delays the real-time task except: - CLI = general interrupt blocked through Windows and drivers (unfortunately, no software can do something against it; However, in Windows the blocking time is limited and almost the driver is responsible for this; in this case the respective driver has to be replaced; it is difficult to determine it, thus only possible by our support (in return of payment). - WBINVD command to flush the entire internal cache (according to experience, only by using Nvidia graphic drivers; only by replacement of the card with an ATI (AMD) the problem can be solved) - C1E = Enhanced Power Save Mode of the CPU (especially, the overdeveloped Intel CPUSs (i7, Xeon.) turns into the idle mode after short breaks, so that the wake up after a timer interrupt can take several milliseconds; that can be switched of in the BIOS (see CIE or similar) or the PC is not real-time capable.
Ordinary Windows activities cannot replace real-time task. Windows has the priority 1, whereas the RealTime tasks have the priorities from 1 to 255. DPC has no influence. To achieve the goal to improve the real-time behavior, only the Dedicated Mode, which supports the exclusive use of single CPU cores in real-time. Without Windows influence the maximum jitter is less than. However, Windows 10 x64 has the so called 'Kernel Patch Protection' in order to restrain access to the OS. Conquiztador Killer V2 Supporter here.
Thus, the code execution of real-time tasks on CPU cores, which are also used by Windows, is not possible. Nevertheless, by using the Dedicated Module it is possible to keep single or multi CPU cores free by the Windows OS ().
In this case, the Kithara real-time system is booted exclusively on the respective CPUs. That enables real-time on a Windows 10 x64 systems with the best real-time features. We distinguish 3 different ways to get real-time on a Windows-PC: • 32 bit applications on a 32 bit Windows • (like 1 and additionally) 64 bit application on a 64 bit Windows • (like 2 and additionally) 32 bit applications on a 64 bit Windows One version of our software only supports 32 bit applications on a 32 bit Windows. An extended version also supports to run 64 bit application on a 64 bit Windows. If 32 bit applications should run on a 64 bit Windows, then the so called “KiK64” (Kithara32-in-Kithara64) is required. This is a special extension to support executing 32-bit code within the 64-bit real-time context. Thus, the KiK64 enables by only one 32-bit application all Windows systems (32 and 64 bit).
For comprehensive and challenging projects it should be noted though, that often a conversion between 32 and 64 bit addresses (code and data) takes place. For a better run-time behaviour it is strongly recommend running rather native 64-bit applications on a 64-bit system.
If you have any questions concerning this topic, feel free to contact us. 'More specified than a specified event is not possible' If a KS_setEvent selected again, eventually the already selected event still persists (1x). The reaction to that depends on, whether the event is a 'auto reset' (default) or a 'manual reset' ( by KSF_MANUAL_RESET at KS_createEvent) event.
At a 'auto reset' event at most one waiting thread is released and in the case of the release, the event is subsequently reset automatically. A 'manual reset' event remains as long as it is reset by KS_resetEvent. Thus, it is also possible to release several waiting threads. The 'manual reset' event is like a gate, which after specification let pass any number of threads until the gate is closed again.